Perpendicular dormer ridge ties directly into main roof ridge with tops at the exact same elevation.
ELEVATION:Flush Ridge Line with Main Roof
CONNECTOR:Simpson Strong-Tie LRU28-2 Bracket
CAPACITY:1,940 lbs downward / 895 lbs uplift
Detail D-04Inspect โ
Multi-Ply Ridge Beam to 6x6 Post Column Cap
Direct load transfer eliminating horizontal thrust on exterior walls for cathedral ceilings.
COLUMN CAP:Simpson CC66 / ECC66 Cap
RIDGE SPEC:3-Ply 1-3/4" x 11-7/8" LVL Beam
CAPACITY:14,250 lbs allowable bearing
SHOP TICKET
Carpenter Cut Schedule & Fabrication Ticket
Exact tip-to-heel lengths, plumb saw angles, birdsmouth notches, and compound miter bevels for cutting rafters on site.
TOTAL TIMBERS:0Framing members count
ESTIMATED LUMBER:0 BFBoard feet material volume
MAIN PLUMB CUT:33.7ยฐ PlumbSaw degree at ridge & fascia
IRC SPAN CHECK:
IRC PASS (84%)
Table R802.5.1 (Click to Fix)
Mark
Role / Location
Dimension
Qty
Tip-to-Heel Length
Ridge Plumb Cut
Birdsmouth (Seat/HAP)
Cheek Bevel
Hardware Connector
Carpentry Guidelines & Fabrication Tolerances:
Plumb Ridge Cuts: Cut with circular saw set to the indicated plumb saw angle. Seat tight against ridge face before nailing.
Birdsmouth Bearing: Horizontal seat cuts are sized to 3.50" bearing over standard 2x4 / 2x6 double top plates. Never exceed 1/4 rafter depth for birdsmouth heel cut per IRC R802.7.
Dormer Valley Jacks: Compound cheek miters require a 45.0ยฐ saw miter combined with the roof pitch bevel angle. Rest flush against the continuous valley sleeper board.
Double Trimmers: Fasten T-1 and T-2 plies together using (2) 10d (3" x 0.128") common nails spaced 12" O.C. staggered along the rafter run.
DETAIL
Simpson Strong-Tie Connection
FASTENING SCHEDULE
ALLOWABLE CAPACITIES
Snap Photo & 1-Line Scale Calibration
Click two corners on any known wall to calibrate scale.
Click 2 points along wall to calibrate
IRC R802.5.1 Span Resolution Helper
โก 1-Click Code Recommendations (Click to Apply)
Or adjust parameters manually:
โ
Edit Caliper Dimension
Floor Plane Measurement Line
โ ๏ธInvalid dimension entered.
โน๏ธDistance clamped to boundary wall.
Target:Post Spacing
Current Span:12' 0" (12.00')
Accepts 14' 6", 174", 14.5', +18", 14' 6 1/2"
โ๏ธ
Dual Design Comparison Breakdown
Side-by-side dimensional, structural, and lumber metrics for Option A vs Option B
OPTION A:Baseline Design
OPTION B:Alternative Design
Framing Metric
Option A
Option B
Delta / Variance
Click and drag in the 3D scene to inspect both options simultaneously in Ghost Overlay mode
This will reset all roof framing, building dimensions, active dormers, post placements, and engineering parameters back to original factory defaults. Any unsaved custom work will be discarded.
๐
Share 3D Roof Model
Interactive Web Link for Clients and Friends
Anyone opening this link can view your exact roof framing, inspect dimensions, and spin the 3D model in real time on any device without installing software.
ENGINEER CONVERSATION PACKET
SHEET R-1: FRAMING PLAN WITH DORMER VALLEYS & TRIMMERS